Tech Tips: How to Bypass a Zone on a DSC Power Series Security Alarm Panel

Welcome to a new, regular feature from Fire Monitoring of Canada!  In these posts, we’ll walk you through “How-To’s” for equipment that we service, and questions that we are regularly asked from you, our customers.

Today, we’ll look at how to bypass a zone with a DSC Power Series Security Alarm panel.  This is applicable if you use your system at home or for your business or commercial security alarm system.  There are many reasons you many wish to bypass a zone, which means that the system will disregard any alarms from that zone when armed.  These include low batteries on devices, construction, or animals or pets.  Here’s step-by-step instructions on how to bypass zones on your DSC Power Series Security alarm panel:

Click Here to  Download a Free User Manual for Your System!

With an LCD Keypad:

PK5500

  • The System Must be disarmed prior to proceeding
  • Press the * Key
  • Press the 1 Key
  • Use the > key to scroll to the zone you wish to bypass
  • Press the * Key on the appropriate zone
  • A “B” should appear next to the zone when the system is bypassed
  • Press the # key repeatedly to exited to the home screen (Ready light should appear)
  • System can now be armed with zones bypassed
  • If armed, the bypass will be removed at next disarming
  • To remove the bypass on the zone, repeat these instructions.

With an Icon Keypad or LED Keypad (looks like): 

i_PK5501_RFK5501i_PK5516_RFK5516

  • The System Must be disarmed prior to proceeding
  • Press the * Key
  • Press the 1 Key
  • Enter the two-digit number of the zone that needs to be bypassed.
  • Press the # key repeatedly to exited to the home screen (Ready light should appear)
  • System can now be armed with zones bypassed.
  • If armed, the bypass will be removed at next disarming
  • To remove the bypass on the zone, enter the two digit code of the zone that needs to be bypassed.

Note: using this feature will leave those zones intentionally unprotected and FMC will not receive alarms from those zones until the bypass is removed.

This tip is applicable for the following alarm panels:

Click Here to  Download a Free User Manual for Your System!

  • DSC PC1616
  • DSC PC1832
  • DSC PC1864
  • DSC PC5010
  • DSC PC5020

Testimonial & Case Study

  • "Fire Monitoring of Canada impressed us with their efficient, professional manner – an approach that not only inspired confidence, but resolved existing service issues with another alarm service provider." - Administrative Coordinator
    View More
  • "Their monitoring & service personnel are knowledgeable, helpful and responsible." - Facilities Manager
    View More
  • "The FMC technician was exceptionally professional in the performance of his duties. He was very organized, focused, safety minded" - Asset Manager
    View More